PowderSafe Type C Enclosure

OPERATOR PROTECTION
POWDER CONTAINMENT

A universal enclosure built with the application and operator in mind

 

AirClean Systems Type C PowderSafe™ balance enclosure incorporates the user-friendly features and chemical fume containment capabilities of the ductless fume hood with airflow dynamics and HEPASafe™ features of the PowderSafe Type B. Thermally fused polypropylene makes the PowderSafe Type C enclosure perfect for powder or solvent weighing, manipulation and enclosing weighing equipment. Fitted with the AirSafe™ automatic safety controller, the Type C PowderSafe has an even laminar flow airstream for accurate weighing.

The entire rear wall of the enclosure is a filtration zone; a clean sweep of all particulate and gases is achieved. This design feature makes the Type C PowderSafe ideal when weighing the lightest powders or the heaviest solvents.

AirClean Systems HEPASafe filter change-out technology, incorporated into each PowderSafe Type C Powder Enclosure, allows the operator to safely and effectively change both the pre-filter and primary HEPA filter. Standard on each Type C enclosure is the AirSafe Automatic Safety Controller. The face velocity on the PowderSafe Type C Enclosures, as preset by the operator, is constantly monitored and maintained by the AirSafe™ Automatic Safety Controller. AirSafe™ monitors the condition of both HEPA filters and provides audible and visible alarms when filter change out is necessary.

 

Standard Features:

  • Horizontal laminar airflow pattern
  • AirSafe™ automatic safety controller
  • Permanent backup HEPA filter
  • Effectively weigh to 7 decimal places
  • Integral vapor-proof fluorescent lighting
  • No ductwork required
  • No installation required - plugs directly into a standard 110V or 220V electrical outlet
  • Polypropylene construction for chemical resistance. The result: NO RUST
  • Constant monitoring of fume hood face velocity with variable airflow control to user preset value
  • Gas phase bonded carbon filtration
  • Lab event timer

 

Safety Features:

  • HEPASafe™ technology allows safe HEPA filter change while enclosure is operational
  • ASHRAE 110 tested
  • Brushless, sparkless blower is post-filter
  • Deep base effectively contains accidental spills
  • Electronic gas detection for real-time gas phase filter monitoring
  • Exhaust air is HEPA filtered, keeping any potential particulate from returning to the room
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Filter safety lockout to ensure correct filter replacement
  • Low airflow alarm warns the user both visually and audibly
  • Real time monitoring of installed filtration bed
  • Shipped fully assembled
  • Tested to UL 61010-1 and CSA C22.2 No. 61010-1

 

Options:

  • Sturdy cart/trolley with locking casters for mobility
  • Hard surface disinfectant

 

Available sizes:

  • 32 inch
  • 48 inch

AirSafe® Automatic Safety Controller

Unit codes:    AC760C  |    AC765C  |    AC770C   |    AC775C  |    AC780C  |    AC785C

How it works


Operator Protection

 

A - Air enters in an even horizontal laminar fashion.

 

B - Contaminated air enters and particulate is removed via electrostatic pre-filtration and HEPA filtration.

 

C - Particulate free air moves upward where it enters the HEPASafe™ filtration area.

 

D - Particulate free air passes into the bonded carbon filtration bed to remove chemical fumes and vapors.

 

E - Clean air is recirculated into the room.

PowderSafe Type C Enclosure