PowderSafe Type B Enclosure

OPERATOR PROTECTION
POWDER CONTAINMENT

Effectively weigh powders to seven decimal places

 

AirClean® Systems PowderSafe™ Type B enclosures usher in a new era of powder weighing and containment technology. Precise airflow control is achieved with the AirSafe™ automatic safety controller. AirSafe™ allows the operator to set the desired face velocity and then automatically maintains that setting. HEPASafe™ filter change technology provides a safe and effective means for replacement of both the pre-filter and primary HEPA filter.

 

Standard Features:

  • AirSafe™ automatic safety controller
  • No installation required - plugs directly into a standard 110V or 220V electrical outlet
  • Integral vapor-proof fluorescent lighting
  • No ductwork required
  • Effectively weigh to 7 decimal places
  • Permanent backup HEPA filter
  • Constant monitoring of fume hood face velocity with variable airflow control to user preset value
  • Horizontal laminar airflow pattern
  • Lab event timer

 

Safety Features:

  • Filter safety lockout to ensure correct filter replacement
  • Brushless, sparkless blower is post-filter
  • Deep base effectively contains accidental spills
  • Low airflow alarm warns the user both visually and audibly
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Shipped fully assembled
  • Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1
  • Real time monitoring of installed filtration bed

Options:

  • Sturdy cart/trolley with locking casters for mobility
  • Hard surface disinfectant

 

Available sizes:

  • 32 inch
  • 48 inch

AirSafe® Automatic Safety Controller

Unit codes:    AC730C  |    AC740C

How it works


Operator Protection

 

A - Turbulence-free laminar flow room air enters enclosure.

 

B - Air is drawn in an even horizontal laminar fashion toward the rear plenum of the enclosure while being mixed with contaminated air.

 

C - Contaminated air enters a pre-filter and then the primary HEPA filter.

 

D - Air cleaned by the primary HEPA filter enters the permanent safety HEPA filter.

 

E - Clean air is recirculated into the room.